Can I use a 2 pole 40 amp breaker with #8 wire for this unit?
Rheem recommends a 50 amp DPST circuit breaker with #6 wire. Please see the image below for reference.
How do I clean the small filter in the back of the machine, can I wash it? The back filter looks like an accordion filter on one side and the reverse side is black plastic, owners manual doesn’t tell how to clean it.
Is this acceptable product for use in the state of Massachusetts? I was unable to find it in their approved code book.
What is SEER rating on RAWL 091caz?
Can I connect this to 6" master pipe to get a 4" branch?
The 406a Saddle Takeoffs can be sized as follows:
4" for 6"-8" pipe
5" for 7"-9" pipe
6" for 8"-10" pipe and so on.
So, yes the 4" can be used off of a 6" pipe.
Are the 2 AA Batteries required to be “Alkaline” or “Lithium” in this version of the Honeywell Outdoor Temperature Sensor?
Does ADP make an evaporator coil that is true multi-position, upflow, downflow, horizontal?
No, they do not make a true multi-positional evaporator coil. It will be either upflow/downflow or horizontal left/horizontal right.